Power | 80 to 100 Watts |
Connectors | N, SMA, TNC, 7/16 |
Frequency range | DC to 6 GHz |
Attenuation range | 0 to 20 dB |
7/16 - 50 OHMS, MALE TO FEMALE
Frequency DC to (GHz) | VSWR max. | Return loss min. (dB) | Power rating (W) | Nom. Attenuation (dB) | Max dev. | Part Number | |
Avg. (W) | Peak (W) | ||||||
3 | 1.35 | 16.5 | 50 | 5,000 | xx | ± 0.7 (1) | R420 0xx 110 |
Available attenuation value: xx = 03, 06, 10 and 20 dB | |||||||
3 | 1.3 | 17.7 | 100 | 5,000 | xx | ± 1 (1) | R420 7xx 110 |
Available attenuation value: xx = 03, 06, 10 and 20 dB |
(1) up to xx = 10
N - 50 OHMS, MALE TO FEMALE
Frequency DC to (GHz) | VSWR max. | Return loss min. (dB) | Power rating (W) | Nom. Attenuation (dB) | Max dev. | Part Number | |
Avg. (W) | Peak (W) | ||||||
3 | 1.35 | 16.5 | 50 | 5,000 | xx | ± 0.7 (1) | R417 0xx 110 |
Available attenuation value: xx = 03, 06, 10, 20 and 30 dB | |||||||
2 | 1.25 | 19.1 | 100 | 5,000 | xx | ± 1 | R417 7xx 118 |
Available attenuation value: xx = 03, 06, 10 and 20 dB |
(1) up to xx = 10
N - 50 OHMS, MALE TO FEMALE, CONDUCTION AND CONVECTION COOLING
Frequency DC to (GHz) | VSWR max. | Return loss min. (dB) | Power rating (W) | Nom. Attenuation (dB) | Max dev. | Part Number | |
Avg. (W) | Peak (W) | ||||||
3 | 1.35 | 16.5 | 40 / 50 | 5,000 | xx | ± 0.7 (1) | R417 0xx 120 |
Available attenuation value: xx = 03, 06, 10, 20 and 30 dB | |||||||
2 | 1.25 | 19.1 | 80 / 100 | 5,000 | xx | ± 1 | R417 7xx 128 |
Available attenuation value: xx = 03, 06, 10 and 20 dB |
(1) up to xx = 10
N - 50 OHMS, MALE TO FEMALE, CONDUCTION COOLING
Frequency DC to (GHz) | VSWR max. | Return loss min. (dB) | Power rating (W) | Nom. Attenuation (dB) | Max dev. | Part Number | |
Avg. (W) | Peak (W) | ||||||
3 | 1.35 | 16.5 | 50 | 5,000 | xx | ± 0.7 (1) | R417 0xx 130 |
Available attenuation value: xx = 03, 06, 10, 20 and 30 dB | |||||||
2 | 1.25 | 19.1 | 100 | 5,000 | xx | ± 1 | R417 7xx 138 |
Available attenuation value: xx = 03, 06, 10 and 20 dB |
(1) up to xx = 10
SMA - 50 OHMS, MALE TO FEMALE
Frequency DC to (GHz) | VSWR max. | Return loss min. (dB) | Power rating (W) | Nom. Attenuation (dB) | Max dev. | Part Number | |
Avg. (W) | Peak (W) | ||||||
3 | 1.35 | 16.5 | 50 | 5,000 | xx | ± 0.7 (1) | R417 1xx 110 |
Available attenuation value: xx = 03, 06, 10, 20 and 30 dB | |||||||
2 | 1.25 | 19.1 | 100 | 5,000 | xx | ± 1 | R417 8xx 118 |
Available attenuation value: xx = 03, 06, 10 and 20 dB |
(1) up to xx = 10
SMA - 50 OHMS, MALE TO FEMALE, CONDUCTION AND CONVECTION COOLING
Frequency DC to (GHz) | VSWR max. | Return loss min. (dB) | Power rating (W) | Nom. Attenuation (dB) | Max dev. | Part Number | |
Avg. (W) | Peak (W) | ||||||
3 | 1.35 | 16.5 | 50 | 5,000 | xx | ± 0.7 (1) | R417 1xx 120 |
Available attenuation value: xx = 03, 06, 10, 20 and 30 dB | |||||||
2 | 1.25 | 19.1 | 100 | 5,000 | xx | ± 1 | R417 8xx 128 |
Available attenuation value: xx = 03, 06, 10 and 20 dB |