The R&S®NGE100B DC Power supply series consists of robust, high-performance, affordable instruments. They offer high efficiency combined with low ripple plus a variety of comfort functions that are not usually found in this class of power supplies.
모델명 | 출력 채널 수 | 최대 출력 파워 | 채널 당 출력 전압 | 채널 당 출력 전류 |
R&S®NGE102B | 2 | 66 W | 0 V ~ 32 V | 0 A ~ 3 A |
R&S®NGE103B | 3 | 100 W | 0 V ~ 32 V | 0 A ~ 3 A |
The circuitry of each single channel is completely separated from the others, there is no connection to chassis ground. This makes it easy to combine the channels to drive bipolar circuitries that might need +12 V/–12 V, for example, and avoids any ground problems in complex DUTs.
Because all channels are electrically equivalent, they can be combined in serial mode to achieve higher voltages. Up to 96 V can be achieved with the R&S®NGE103B, up to 64 V with the R&S®NGE102B. In parallel mode, the channels can be bundled for higher current. Up to 6 A can be achieved when combining two channels. Using all three channels of the R&S®NGE103B, even 9 A are possible.
For each channel, users can separately set the:
If such a limit is reached, the affected output channel will be automatically switched off and a message will be displayed. The overcurrent protection can be linked to other channels (FuseLink function). In this case, the channel exceeding the maximum current level and all linked channels will be switched off.
All operating conditions are shown clearly on the 3.5" QVGA display (320 × 240 pixel), including the output power and the status of any protective functions. Colors indicate the different operating conditions:
Electrical specifications | ||
Number of output channels | 2/3 | |
Total output power | max. 66 W/100 W | |
Maximum output power per channel | 33,6 W | |
Output voltage per channel | 0 V to 32 V | |
Maximum output current per channel | 3 A | |
Voltage ripple and noise (20 Hz to 20 MHz) | typ. < 1.5 mV (RMS) | |
< 20 mV (peak-to-peak) (meas.) | ||
Current ripple and noise (20 Hz to 20 MHz) | < 2 mA (RMS) (meas.) | |
Load recovery time*1) | < 200 µs (meas.) | |
Programming/readback resolution | Voltage | 10 mV |
Current | 1 mA | |
Readback accuracy (± (% of output + offset)) | Voltage | < 0.1% + 20 mV |
Current | < 0.1% + 5 mA | |
Special functions | ||
Measurement functions | voltage, current, power, energy | |
Protection functions | OVP, OCP, OPP, OTP | |
FuseLink function | ● | |
Fuse delay at power-up | ● | |
Sense function | - | |
Sink mode | - | |
Output sequencing | - | |
Trigger input/output | - | |
Arbitrary function | ● (EasyArb) | |
Analog/modulation interface | – | |
Data logging | - | |
Display and interfaces | ||
Display | 3,5" QVGA | |
Rear panel connections | ||
Remote control interfaces | standard: USB; optional: LAN, WLAN | |
General data | ||
Dimensions (W × H × D) | 222 × 97 × 310 mm | |
Weight | 4.9 kg/5.0 kg | |
Rack installation | R&S®HZC95 option | |
*1) 10% to 90% load change within a band of ± 20 mV of set voltage. |
제목 | 다운받기 |
---|---|
R&S ®NGE100B 파워서플라이 시리즈 - 데이터시트 | 다운로드 |